Project Description
Lab Molecular Distillation Equipment cbd
Jacketed material feeding tank.
Feeding type: Differential pressure PTFE valve & Gear pump feeding optional.
Glass flask collection flask, gear pump collection type optional.
Lab Molecular Distillation Equipment cbd
Short path (molecular) distillation system is considered as the safest mode of separation and to purify the thermally unstable molecules & related compounds with low volatility & elevated boiling point.
In the high vacuum environment, molecular distillation has the advantages of low distillation temperature, short heating time and rapid separation.
Technical parameters of MDS-6A short path molecular distillation equipment:
Main body | Model | MDS-6A |
Material tank | 1L jacketed glass tank | |
Material charging | Differential pressure PTFE valve. | |
Feed rate 0.5L~3L/H | ||
Evaporator | Evaporation area 0.06㎡ | |
Film forming way:scraper (roller is optional) | ||
Material:316L | ||
Mechanical seal (Magnetic seal is optional) | ||
Film forming motor:200W motor, electronic speed regulation. | ||
Cold trap | 1. 0.2㎡chiller cooling cold trap | |
2. 1L liquid nitrogen cold trap | ||
3. Dual-purpose(chiller & liquid nitrogen cold trap dual purpose). | ||
Choose 1 in above 3 types | ||
Heavier component discharge | 29# Grinding mouth adapter | |
5L glass bottle 1pcs, bottle holder 1pcs | ||
Lifting table 1pcs | ||
Lighter component discharge | 29# Grinding mouth adapter | |
5L glass bottle 1pcs, bottle holder 1pcs | ||
Lifting table 1 pcs | ||
Material pipeline | Jacketed insulation | |
Shelf & assemble | 304 stainless steel pipe | |
Accessory | Vacuum | 1. No-load < 10PA |
2. No-load < 5PA | ||
3. No-load < 0.01PA rotary vane molecular pump set (Single phase 220V) | ||
Vacuum gauge | Resistance / thermocouple vacuum transmitter | |
Main evaporator heating | 300℃/3KW
| |
Raw material section insulation | 200℃/1.5KW | |
Heavier component insulation | 200℃/1.5KW | |
Lighter componentcondensation & insulation (CBD lighter component could share with material feeding tank) | Internal condenser — High & low temperature all-in-one machine | |
Insulation —200℃/1.5KW | ||
External cold trap cooling | 1. Liquid nitrogen cold trap | |
Or 2. Chiller |
TOPTION as CE certified, ISO approved molecular distillation equipment manufacturer, with more than 15 years production experience, our strong engineers team has more than 24 years operating & design experience, support flexible design & professional customize. Contact info@toptionlab.com to get free consult, welcome factory visit or overseas service is available.
Lab – pilot – industry wide capacity range, multistages customization is available
MDS-6B Lab Short Path Distillation
- Jacketed stainless steel material feeding system.
- Gear pump material feeding type.
- Glass flask collection type.
Technical parameters of short path molecular distillation equipment:
Main body | Model | MDS-6B short path molecular distillation system |
Material tank | 3L jacketed stainless steel tank | |
2 sight glass at top, with insulated ball valve | ||
Material charging | Gear pump | |
Flow 0.5L~3L/H | ||
120W motor, electronic speed regulation. | ||
Evaporator | Evaporation area 0.06㎡ | |
Film forming way: scraper (roller is optional) | ||
Material:316L | ||
Mechanical seal (Magnetic seal is optional) | ||
Film forming motor:200W motor, electronic speed regulation. | ||
Cold trap | 1. 0.2㎡chiller cooling cold trap | |
2. 1L liquid nitrogen cold trap | ||
3. Dual-purpose(chiller & liquid nitrogen cold trap dual purpose). | ||
Choose 1 in above 3 types | ||
Heavier component discharge | 29# Grinding mouth adapter | |
5L glass bottle 1pcs, bottle holder 1pcs | ||
Lifting table 1pcs | ||
Lighter component discharge | 29# Grinding mouth adapter | |
5L glass bottle 1pcs, bottle holder 1pcs | ||
Lifting table 1 pcs | ||
Material pipeline | Jacketed insulation | |
Shelf & assemble | 304 stainless steel pipe | |
Accessory | Vacuum | 1. No-load < 10PA |
2. No-load < 5PA | ||
3. No-load < 0.01PA rotary vane molecular pump set (Single phase 220V) | ||
Vacuum gauge | Resistance / thermocouple vacuum transmitter | |
Main evaporator heating | 300℃/3KW | |
Raw material section insulation | 200℃/1.5KW | |
Heavier component insulation | 200℃/1.5KW | |
Lighter component condensation & insulation (CBD lighter component could share with material feeding tank) | Internal condenser — High & low temperature all-in-one machine GD-10200-5 | |
Insulation —200℃/1.5KW | ||
External cold trap cooling | 1. Liquid nitrogen cold trap 。 | |
Or 2. Chiller |
MDS-6C molecular distillation medical definition
- Jacketed stainless steel material feeding tank.
- Gear pump material feeding type.
- Gear pump collection type.
- E series customize.
- Filter net customize – In the hemp / cbd liquid, worried about the presence of cellulose that has not been filtered clean, again filtered. Ensure good separation effect, high quality oil and equipment maintenance, multiple functions
Main body | Model | MDS-6C molecular distillation process |
Material tank | 3L jacketed stainless steel tank | |
2 sight glass at top, with insulated ball valve. | ||
Material charging | Gear pump | |
Flow 0.5L~3L/H | ||
120W motor, electronic speed regulation. | ||
Evaporator | Evaporation area 0.06㎡ | |
Film forming way:scraper (roller is optional) | ||
Material:316L | ||
Mechanical seal (Magnetic seal is optional) | ||
Film forming motor:200W motor, electronic speed regulation. | ||
Cold trap | 1. 0.2㎡ chiller cooling cold trap | |
2. or 1L liquid nitrogen cold trap | ||
3. Dual-purpose(chiller & liquid nitrogen cold trap dual purpose). | ||
Choose 1 in above 3 types | ||
Heavier component discharge | Gear pump | |
Flow 0.5L~3L/H | ||
120W motor, electronic speed regulation. | ||
Lighter component discharge | Gear pump | |
Flow 0.5L~3L/H | ||
120W motor, electronic speed regulation. | ||
Material pipeline | Jacketed insulation | |
Shelf & assemble | 304 stainless steel pipe | |
Accessory | Vacuum | 1. No-load <10PA |
2. No-load < 5PA | ||
3. No-load < 0.01PA rotary vane molecular pump set (Single phase 220V) | ||
Vacuum gauge | Resistance / thermocouple vacuum transmitter | |
Main evaporator heating | 300℃/3KW | |
Raw material section insulation | 200℃/1.5KW | |
Heavier component insulation | 200℃/1.5KW | |
Lighter componentcondensation & insulation (CBD lighter component could share with material feeding tank) | Internal condenser — High & low temperature all-in-one machine | |
Lighter component insulation —200℃/1.5KW | ||
External cold trap cooling | 1. Liquid nitrogen cold trap | |
Or 2. Chiller . |
Application of molecular distillation equipment:
Molecular distillation is applied for creating a high value clear distillate from Plant Oil Concentrates, such as refine cannabis and hemp concentrates into a golden clear distillate that can be infused into a variety of edible products or fine oils to be used in vape cartridges or other products.