Project Description
Laboratory Thermostatic Bath
-40℃~200℃ wide temp. range.
Heating thermostatic water bath, cooling thermostatic bath optional.
CE certified reliable quality guarantee, OEM customize.
Laboratory Thermostatic Bath
- Control System
The latest dedicated software research and development of self-made temperature control technology, with a high standard PT100 and the full import of electronic components and other components.
The software system is easy to correct the display temperature and the actual temperature error, the temperature correction resolution up to 0.01 ℃, so that the display temperature is accurate.
With over-temperature protection, over-temperature alarm alarm, you can set the over-temperature alarm temperature, over-temperature can automatically cut off the load.
Intelligent software temperature stability, PID automatically according to different media automatically set the best parameters, special users also manually re-adjust the parameters.
Use the software digital lock control system settings, to avoid unintentional personnel to misuse, to ensure that the experimental process data is correct.
Accurate temperature control, so that the temperature inside the work tank quickly and steadily.
Press the “power” button to turn off all the functions of the instrument, but the instrument can also show the temperature inside the tank naturally rise and fall process.
- Cooling System
High efficiency fully enclosed compressor refrigeration, cooling speed, with overheating over current and other multiple protection.
- Circulating system
Advanced internal circulation and external circulation system, the internal circulation makes the temperature uniform and stable, the external circulation pump output flow temperature liquid to establish the machine outside the second constant temperature field, but also as a cold source to the cooling machine outside the experimental container.
Technical parameters of DC-II series of low temperature thermostat bath:
Model | Temp. range(℃) | Temp. fluctuation (℃) | Digital display resolution (℃) | Capacity(mm3) | Bath dimension (mm2) | Bath depth (mm) | Pump circulate flow(L/min) |
DC0506-II | -5~160 | ±0.1~0.2 | 0.1 | 250*200*150 | 180*150 | 150 | 5 |
DC1006-II | -10~160 | ±0.1~0.2 | 0.1 | 250*200*150 | 180*150 | 150 | 5 |
DC2006-II | -20~160 | ±0.1~0.2 | 0.1 | 250*200*150 | 180*150 | 150 | 5 |
DC3006-II | -30~160 | ±0.1~0.2 | 0.1 | 250*200*150 | 180*150 | 150 | 5 |
DC1010-II | -10~160 | ±0.1~0.2 | 0.1 | 250*200*200 | 180*150 | 200 | 5 |
DC2010-II | -20~160 | ±0.1~0.2 | 0.1 | 250*200*200 | 180*150 | 200 | 5 |
DC3010-II | -30~160 | ±0.1~0.2 | 0.1 | 250*200*200 | 180*150 | 200 | 5 |
DC0515-II | -5~160 | ±0.1~0.2 | 0.1 | 280*250*200 | 235*180 | 200 | 5 |
DC1015-II | -10~160 | ±0.1~0.2 | 0.1 | 280*250*200 | 235*180 | 200 | 5 |
DC2015-II | -20~160 | ±0.1~0.2 | 0.1 | 280*250*200 | 235*180 | 200 | 5 |
DC0520-II | -5~160 | ±0.1~0.2 | 0.1 | 280*250*300 | 235*180 | 300 | 5 |
DC1020-II | -10~160 | ±0.1~0.2 | 0.1 | 280*250*300 | 235*180 | 300 | 5 |
DC4008-II | -40~160 | ±0.1~0.2 | 0.1 | 270*200*150 | 180*180 | 150 | 5 |
DC0530-II | -5~160 | ±0.1~0.2 | 0.1 | 420*330*230 | 310*280 | 230 | 5 |
DC1030-II | -10~160 | ±0.1~0.2 | 0.1 | 420*330*230 | 310*280 | 230 | 5 |
Technical parameters of DC-IIX series of high and low temperature thermostat bath (LCD display) – Inner loop:
Model | Temp. range (℃) | Temp. fluctuation (℃) | Digital display resolution (℃) | Capacity (mm3) | Bath dimension (mm2) | Bath depth (mm) |
DC0506-IIX | -5~220 | ±0.05~0.2 | 0.01 | 250*200*150 | 180*140 | 150 |
DC1006-IIX | -10~220 | ±0.05~0.2 | 0.01 | 250*200*150 | 180*140 | 150 |
DC2006-IIX | -20~220 | ±0.05~0.2 | 0.01 | 250*200*150 | 180*140 | 150 |
DC3006-IIX | -30~220 | ±0.05~0.2 | 0.01 | 250*200*150 | 180*140 | 150 |
For outer loop could change to 5L/min, more models thermostatic water bath PDF catalogue, please contact info@toption-china.com 24h/7days online service.
Cooling Heating Thermostatic Circulator Bath
- -40~200℃ Cooling Heating Thermostatic
This full closed cycle thermostatic bath is widely applied to the field of bioengineer, madicine, food, chemical industry, metallurgy and petroleum, offering ideal constant temperature equipment for the research institute, high-education institute, quality control department of lab and factory.
- Low temp. thermostatic bath
1. Refrigeration system
– Single compressor cascade refrigeration technology.
– Faster cooling speed, energy saving, high efficient, low noise.
– Brand compressor.
2. Evaporator
– Using nickel-plated copper.
3. Control system and data records
– 7inch color touch screen display.
– Real-time temperature record.
– Temp. curve record, export to USB (excel format).
4. Safety system
– Refrigeration system of high and low pressure protection and display.
– Condensing temperature display and protection.
– A variety of fault alarm (overtemperature alarm, sensor alarm, high pressure alarm,
compressor overheat alarm, compressor overheat alarm).
– Boot delay protection.
– All parts are safety grounding.
Get thermostatic circulating bath PDF catalogue welcome contact info@toption-china.com 24h/7days.