  • 5L, 10L, 20L, 50L, 100L, 150L, 200L capacity.

  • Glass and stainless steel material optional.

  • CE certification, professional customize.

Send Inquiry

Ultrasonic Chemical Reactors

TOPTION ultrasonic series instruments use the cavatition of ultrasonic to disperse the coacervate particle.

Ultrasonic Emulsification Reactor through its “cavitation effect” to realize the emulsification of oil blended with water, emulsification of water mixed with oil, the mixture and homogenization of dispersed phase and continuous phase, it’s modern chemical technology to instead of propeller, colloid mill and other traditional emulsification technology.

Technical parameters of ultrasonic homogeneous reactor:

Model

TUER-5GLS  

TUER-5GLD

TUER-10GLS   

TUER-10GLD

TUER-20GLS   

TUER-20GLD

Ultrasound   Method

Energy-gathered circulation multiple-step type

CapacityL

5

10

20

Stir Motor PowerW

100

150

200

Ultrasonic   Frequency

20KHz

20KHz

20KHz

Standard   Ultrasonic Probe

40*1

40*1

40*1

Ultrasonic   Power(w)

100~2400   Adjustable

100~2400   Adjustable

100~2400   Adjustable

Circulation Stirring Rate (rpm)

0~1000 Integrated Digital Display, Stepless Timing

0~1000 Integrated Digital Display, Stepless Timing

0~1000 Integrated Digital Display, Stepless Timing

Controlled   Temperature ℃
Optional

0–100

0–100

0–100

Reactor Material

SS304/Glass

SS304/Glass

SS304/Glass

Applicable   Medium

Volatility   /  Fixed Hydrocarbon

Volatility   /  Fixed Hydrocarbon

Volatility   /  Fixed Hydrocarbon

Application

Laboratory   & Pilot

Laboratory   & Pilot

 Pilot

Note: Professional Customization is provided, high temp. device, low temp. device,   constant temp. device are available (-5℃ ~ 80℃).

Stainless Steel Ultrasonic Homogeneous Reactor

  • Mechanical drive stirring motor, makes material mixing more uniform.
  • Multi ultrasonic working head combined together, large power, much better emulsification result.
  • In-built circulating system makes sample get more uniform mixing, no dead angle.
  • Downward discharging valve, more convenient for material discharging.
  • Vertical electric stirring makes material mixing more uniform.

Technical parameters of ultrasonic chemical reactor:

Model

TUER-5SUS /

TUER-5SUD

TUER-5SLS /

TUER-5SLD

TUER-10SUS /

TUER-10SUD

TUER-10SLS /

TUER-10SLD

TUER-20SUS /

TUER-20SUD

TUER-20SLS /

TUER-20SLD

Ultrasound Method

Energy-gathered circulation multiple-step type

CapacityL

5

10

20

Stir Motor PowerW

100

150

200

Ultrasonic Frequency

20KHz

20KHz

20KHz

Standard Ultrasonic Probe

40*1

40*1

40*1

Ultrasonic Power(w)

100~2400 Adjustable

100~2400 Adjustable

100~2400 Adjustable

Circulation Stirring Rate (rpm)

0~1000 Integrated Digital Display,Stepless Timing

0~1000 Integrated Digital Display,Stepless Timing

0~1000 Integrated Digital Display,Stepless Timing

Controlled Temperature ℃
Optional

0–100

0–100

0–100

Reactor Material

SS304 (single layer & double layer optional, “U” shape & Cylinder shape optional. )

Applicable Medium

Volatility /  Fixed Hydrocarbon

Volatility /  Fixed Hydrocarbon

Volatility /  Fixed Hydrocarbon

Application

Laboratory & Pilot

Laboratory & Pilot

 Pilot

Note: Professional Customization is provided, high temp. device, low   temp. device, constant temp. device are available (-5℃ ~ 80℃).

50L, 100L, 150L, 200L ultrasonic emulsifier reactor customization

High Pressure Ultrasonic Reactor System

TOPTION this type ultrasonic reactor is often used in laboratory extraction and chemistry reaction research, which has solve amplitude transformer and reactor sealing problems, could equip various types chemical reactors’ accessories under high temperature, achieve reaction system gas separation and vapor phase condensation & reflux.

So could use ultrasonic disperse, crush, and excitation etc multiple effect to break the solvent structure of chemical reaction material in reactor, improve reaction activity, disperse and crush particles, reduce its radius.

Technical parameters of high pressure ultrasonic reactor:

Model

Pressure   (Mpa)

Temperature℃

Capacity ml

Ultrasonic power (w)

TUHP-150ml

-0.1-12.5

RT-300

150ml

10-500w continuously adjustable

TUHP-250ml

-0.1-12.5

RT-300

250ml

20-1000w continuously adjustable

TUHP-500ml

-0.1-12.5

RT-300

500ml

100-1200w continuously adjustable

TUHP-750ml

-0.1-12.5

RT-300

750ml

200-1500w continuously adjustable

TUHP-1L

-0.1-12.5

RT-300

1000ml

300-1800w continuously adjustable
TUHP-2L

-0.1-12.5

RT-300

2000ml

400-3000w continuously adjustable
TUHP-5L

-0.1-12.5

RT-300

5000ml

500-3500w continuously adjustable
TUHP-10L

-0.1-12.5

RT-300

10000ml

800-5000w continuously adjustable

Mechanical stirring reactor lid is available, could achieve the exchange of mechanical stirring and energy-gathered ultrasonic, or you also could install mechanical stirring at the top of reactor, install energy-gathered ultrasonic at the bottom.

Special capacity, special material, special pressure and special temperature could customize:

  • Max pressure could reach 40Mpa.
  • Max temperature could reach 400℃.
  • Low temperature could reach -50℃.
  • Max ultrasonic power could customize 100KW.
  • Max capacity could customize 1000L.